Hi all,
Could it be that the new dictionary included in the 2.15 release
contains an error on line 38 (see below)? I changed type binary to
abinary but that resulted in strange errors (see logfile excerpt below).
I then changed the type to integer which in our case is right (should be
string according to standards, but we use Ascend/Alcatel SMC).
Mike, could you check the workings of the abinary type? I haven't had a
look at the code yet, but this seems strange.
- Joost.
dictionary line 38:
ATTRIBUTE Proxy-State 33 binary
logfile:
Mon Apr 3 12:46:23 2000: NOTICE: SIGHUP received: restarting
Mon Apr 3 12:46:24 2000: ERR: Bad format in dictionary
'/opt/APPradius/etc/dictionary' at line 38
Mon Apr 3 12:46:24 2000: INFO: Server started
Mon Apr 3 12:46:30 2000: ERR: Attribute number 33 (vendor ) is not
defined in your dictionary
Mon Apr 3 12:46:44 2000: ERR: Attribute number 33 (vendor ) is not
defined in your dictionary
Mon Apr 3 12:46:46 2000: ERR: Attribute number 33 (vendor ) is not
defined in your dictionary
Mon Apr 3 12:46:46 2000: ERR: Attribute number 33 (vendor ) is not
defined in your dictionary
Mon Apr 3 12:46:51 2000: NOTICE: SIGHUP received: restarting
Mon Apr 3 12:46:52 2000: INFO: Server started
Mon Apr 3 12:46:55 2000: INFO: Radius::AuthKPNLDAP: Authentication
failed for [EMAIL PROTECTED]
Mon Apr 3 12:46:55 2000: WARNING: Could not parse Proxy-State: generic
out drop ==
Mon Apr 3 12:47:03 2000: WARNING: Could not parse Proxy-State: generic
out drop ==
Mon Apr 3 12:47:10 2000: INFO: Radius::AuthKPNLDAP: Authentication
failed for [EMAIL PROTECTED]
Mon Apr 3 12:47:10 2000: WARNING: Could not parse Proxy-State: generic
out drop ==
Mon Apr 3 12:47:17 2000: WARNING: Could not parse Proxy-State: generic
out drop ==
Mon Apr 3 12:47:36 2000: WARNING: Could not parse Proxy-State: generic
out drop ==
Mon Apr 3 12:47:38 2000: WARNING: Could not parse Proxy-State: generic
out drop ==
Mon Apr 3 12:47:39 2000: NOTICE: SIGHUP received: restarting
Mon Apr 3 12:47:39 2000: INFO: Server started
- Joost.
--
================================================
Joost Stegeman
Service Developer Integration Services
KPN
OVN BBT/IP Integration Services
tel. 070 - 371 37 83
fax. 070 - 371 26 38
E-mail: [EMAIL PROTECTED]
================================================
===
Archive at http://www.starport.net/~radiator/
Announcements on [EMAIL PROTECTED]
To unsubscribe, email '[EMAIL PROTECTED]' with
'unsubscribe radiator' in the body of the message.