Hello Scott -
You would use two instances of Radiator with different port bindings
using the AuthPort and AcctPort configuration parameters.
on the first Radiator
AuthPort 1645
AcctPort 1646
and on the second
AuthPort 1812
Acctport 1813
hth
Hugh
At 18:56 +1000 28/8/00, Scott Penno wrote:
>Good evening all,
>
>I'm relatively new to using RADIUS (and Radiator) but have stumbled on a
>minor problem. We have a number of devices that will only use the older
>ports for RADIUS (1645, 1646) and a number of devices that will only use the
>newer ports for RADIUS (1812, 1813). Is there any way I can have Radiator
>listen to both groups of ports? Or is the only way this can be acheived by
>running two instances of Radiator, each bound to a different IP address?
>
>Regards,
>
>Scott Penno
>KNX (Asia Pacific) Pty. Ltd.
>
>===
>Archive at http://www.starport.net/~radiator/
>Announcements on [EMAIL PROTECTED]
>To unsubscribe, email '[EMAIL PROTECTED]' with
>'unsubscribe radiator' in the body of the message.
--
--
Radiator: the most portable, flexible and configurable RADIUS server
anywhere. SQL, proxy, DBM, files, LDAP, NIS+, password, NT, Emerald,
Platypus, Freeside, Interbiller, TACACS+, PAM, external, etc, etc.
Available on Unix, Linux, FreeBSD, Windows 95/98/2000, NT, MacOS X.
===
Archive at http://www.starport.net/~radiator/
Announcements on [EMAIL PROTECTED]
To unsubscribe, email '[EMAIL PROTECTED]' with
'unsubscribe radiator' in the body of the message.