Hi Guys,
Well, I got my wholesale system working great!
Thanks for all the help Hugh.
Anyways, I have a few wholesalers who have decided
that they want to have backup radius proxy servers. This is how I am doing
it.
<AuthBy
GROUP>
Identifier AuthDNIS RewriteUsername s/^NET\/(.*)$/$1/ <AuthBy RADIUS> Host 216.177.x.xxx,216.177.x.yyy Secret G4-Net AuthPort 1645 AcctPort 1646 Retries 2 RetryTimeout 2 FailureBackoffTime 60 </AuthBy> AuthLog fail AuthLog login RejectHasReason </AuthBy> The primary server works in this case, but when the
primary goes down, the backup does indeed start recieving requests, however,
users do not get authenticated. The secondary server does authenticate the
request, but Radiator does not pass the access accept through. Any ideas
anyone?
--Tom
Tom Daly
Network Operations Administrator G4 Communications Corp. / Metro2000 Internet Services E: [EMAIL PROTECTED] / W3: www.metro2000.net |
- Re: (RADIATOR) Radus Proxy Tom Daly
- Re: (RADIATOR) Radus Proxy Hugh Irvine