Are you putting spaces after the username in the database?

-Ronan

-----Original Message-----
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]] On
Behalf Of Shaun Eck
Sent: Thursday, 21 February, 2002 16:56
To: [EMAIL PROTECTED]
Subject: (RADIATOR) Radiator configuration File and Password


Hi

I would like to get some assistance on how to have the password clipped
from within the configuration file radius.cfg.  Let me explain further.
We have configured the radius.cfg file to be able to authenticate both
from a file and from a database.  The authentication is done by
implementing the subscribers table as recommended by the installation
process.  However we are denied access when the user that is logging-in
is in the subscribers table.  We have found that by including the
additional spaces in the password that equal the size of the password
,field define in the subscribers table, only then are we able to login.

Table: subscribers
           username    char(12)

Example:
Login Name:  vcas
Password:     vcas+8spaces

===
Archive at http://www.open.com.au/archives/radiator/