Hi Hugh,

I changed as you suggested '-' into ':', but it seems like still error.

Mon Nov 25 10:11:01 2002: ERR: There is no value named 16:3049 for attribute Class. Using 0.
Mon Nov 25 10:11:01 2002: ERR: There is no value named 16:3049 for attribute Class. Using 0.
Mon Nov 25 10:11:01 2002: DEBUG: do query is: insert into ACCOUNTING (USERNAME,ACCTSTATUSTYPE,class_id,TIME_STAMP,NASPORT,CALLINGSTATIONID,ACCTDELAYTIME,CONTRACTID,ACCTSESSIONID,ACCTINPUTOCTETS,FRAMEDIPADDRESS,ACCTSESSIONTIME,ACCTOUTPUTOCTETS) values ('ynbstone','Stop',substring('16:3049',1,locate(':','16:3049')-1),1038190261,'434','11305106',0,substring('16:3049',locate(':','16:3049')+1),'00001D6F',1631,'202.179.xx.xx',18,836)


Ganbold


At 09:47 AM 11/25/2002 +1100, you wrote:

Hello Ganbold -

I think a better approach would be to use a different delimiter than
"-", which I suspect is confusing things.

What about using ":" (colon) instead?

Please try it and let me know what happens.

regards

Hugh


On Sunday, Nov 24, 2002, at 17:45 Australia/Melbourne, Ganbold wrote:

Hi Hugh,

Following is the part of the radius config file where I'm
concatenating 2 integer values into one string and  putting into 2
integer field from
concatenated string:
.....

        AuthSelect select
ENCRYPTEDPASSWORD,CHECKATTR,REPLYATTR,concat(CLASS_ID,'-',CONTRACTID)
from SUBSCRIBERS where USERNAME='%n' and STATUS='Active'

        EncryptedPassword

        AuthColumnDef 0, Encrypted-Password, check
        AuthColumnDef 1, GENERIC, check
        AuthColumnDef 2, GENERIC, reply
        AuthColumnDef 3, Class, reply

...
        AcctColumnDef
class_id,Class,integer,substring('%{Class}',1,locate('-','%{Class}')-> 1)
        AcctColumnDef
CONTRACTID,Class,integer,substring('%{Class}',locate('-> ','%{Class}')+1)
...

In dictionary file Class is defined as string.

Ganbold


At 03:24 PM 11/23/2002 +1100, you wrote:

Hello Ganbold -

What definition do you have for "Class" in your dictionary (looks like
"integer")?

It should be defined as "string".

Here is the entry from the standard dictionary:

ATTRIBUTE       Class                   25      string

regards

Hugh


On Friday, Nov 22, 2002, at 17:20 Australia/Melbourne, Ganbold wrote:

Hi,

I'm having trouble with Radiator 3.3.1. I'm putting concatenated
value
to Class attribute.
But in radius logfile it says ERR: There is no value named 19-400 for
attribute Class. Using 0.
In insert statement it gets Class value and gets part of string and
puts into 2 different int field.

Following is the part of logfile and insert statement.

Ganbold

------Logfile --------------------------

Thu Nov 21 19:53:08 2002: ERR: There is no value named 19-400 for
attribute Class. Using 0.
Thu Nov 21 19:53:08 2002: ERR: There is no value named 19-400 for
attribute Class. Using 0.
Thu Nov 21 19:53:08 2002: DEBUG: do query is: insert into ACCOUNTING
(USERNAME,ACCTSTATUSTYPE,class_id,TIME_STAMP,ACCTTERMINAT
ECAUSE,NASPORT,CALLINGSTATIONID,ACCTDELAYTIME,CONTRACTID,ACCTSESSIONI D, ACCTINPUTOCTETS,FRAMEDIPADDRESS,ACCTSESSIONTIME,ACCTOUT
PUTOCTETS) values
('skytel','Stop',substring('19-400',1,locate('-','19-400')-
1),1037879588,'User-Request','56','11366801',0,su
bstring('19-400',locate('-','19-
400')+1),'000F6CE3',511690,'202.179.x.xx',3131,7864103)

===
Archive at http://www.open.com.au/archives/radiator/
Announcements on [EMAIL PROTECTED]
To unsubscribe, email '[EMAIL PROTECTED]' with
'unsubscribe radiator' in the body of the message.
--
Radiator: the most portable, flexible and configurable RADIUS server
anywhere. Available on *NIX, *BSD, Windows 95/98/2000, NT, MacOS X.
-
Nets: internetwork inventory and management - graphical, extensible,
flexible with hardware, software, platform and database independence.

--
Radiator: the most portable, flexible and configurable RADIUS server
anywhere. Available on *NIX, *BSD, Windows 95/98/2000, NT, MacOS X.
-
Nets: internetwork inventory and management - graphical, extensible,
flexible with hardware, software, platform and database independence.

===
Archive at http://www.open.com.au/archives/radiator/
Announcements on [EMAIL PROTECTED]
To unsubscribe, email '[EMAIL PROTECTED]' with
'unsubscribe radiator' in the body of the message.