Marius: At 11:34 PM 1/2/03 +0100, you wrote:
The replication is controlled by the MySQL replication code. For all intent it is real time. Each master keeps a journal, each slave keeps track where it is in the master's journal. After any loss of connectivity the slave will start where it left off and bring itself up-to-date. In a circular master/slave-slave/master configuration. Any changes applied to either database while connectivity is down will be applied when connectivity is re-established. This has shown itself to work flawlessly with no intervention necessary.First of all thanks for your feedback DavidSome questions: -how often you do the backend replication? How often can the sessiondatabase be replicated? The point is -Let's suppose on the x replication time there are 100 ports in use(from 200) and close to the x+1 replication there are 200 ports in use but a failure is happening before the replication so the radius will check the secondary database and will still allow 100 extra connections!
The script does not know anything about the database replication as such. It simply queries the session database its pointed at (in my case the "secondary") and verifies that each session is still active (via SNMP, other means are available). If it finds one that is not active, it deletes it. The database replication code then takes care of making the same change in the "master." The script is running as a cron on the secondary database server.-the script identifies which database is prim or sec(basically the one that is leading)? By the way on which machine is running?
This is not correct. We use the standard <SessionDatabase SQL> declaration in radius.cfg with a primary and secondary defined. Authentication is from flat file (<AuthBy FILE>), for robustness, with a "DefaultSimultaneousUse" of 1. Radiator is making all simultaneous-use checks against the session database.-if I got it correctly the bellow mentioned cron basically is doing what the Simultaneous -use is doing when the port limit is almost reached(checking if the items that are shown in the session database are really set-up or not into the NAS).The only difference is that this task is performed every 5 minutes in your case. If this is the case does this regular check have any impact in a network with 100.000 ports(SNMPs all over) and above?
The cron script is just to correct the session database in the event of lost stop (accounting ???) packets from the NAS. As Hugh has pointed out, the RADIUS protocol uses UDP and therefore is susceptible to lost packets. As Hugh also pointed out in his post, Radiator is very self healing in that it performs a delete on the NAS/NASPORT combination before doing an insert. The situation will eventually correct itself when the NAS/NASPORT combination is re-used, but in the mean time the user is "locked out" as there is an entry in the session database. The cron script will detect and correct this situation within a few minutes. I have tried running the script more frequently, but the snmp queries are slow and take awhile to complete. Five minutes seems to be a good compromise of overhead verses how long a user may find themselves "locked" out of the system.
Regards,
Dave
===