Hello Tom -


You can use the "PacketTrace" parameter to change the log level in different places in the configuration file.

Using Radar (or your own connection to a Monitor clause) you can do this dynamically.

See section 6.5.17 in the Radiator 3.7.1 reference manual ("doc/ref.html").

For details on Radar see the following URL:

www.open.com.au/radar

For details on the Monitor clause see sections 6.61 and 23 in the manual.

regards

Hugh


On 16/12/2003, at 3:53 AM, McGrath, Thomas J. wrote:


All;

        Does anyone know if you can set a different logging level for each
handler?

I would like to audit a few authentication requests to the RADIUS
Radiator server for specific handlers. It would be ideal to have them set
to Trace 4 while setting other common used ones to a lower lever.


Thanks,
Tom McGrath
===
Archive at http://www.open.com.au/archives/radiator/
Announcements on [EMAIL PROTECTED]
To unsubscribe, email '[EMAIL PROTECTED]' with
'unsubscribe radiator' in the body of the message.



NB: have you included a copy of your configuration file (no secrets), together with a trace 4 debug showing what is happening?

--
Radiator: the most portable, flexible and configurable RADIUS server
anywhere. Available on *NIX, *BSD, Windows, MacOS X.
-
Nets: internetwork inventory and management - graphical, extensible,
flexible with hardware, software, platform and database independence.
-
CATool: Private Certificate Authority for Unix and Unix-like systems.

===
Archive at http://www.open.com.au/archives/radiator/
Announcements on [EMAIL PROTECTED]
To unsubscribe, email '[EMAIL PROTECTED]' with
'unsubscribe radiator' in the body of the message.

Reply via email to