Hello Tom -
You can use the "PacketTrace" parameter to change the log level in different places in the configuration file.
Using Radar (or your own connection to a Monitor clause) you can do this dynamically.
See section 6.5.17 in the Radiator 3.7.1 reference manual ("doc/ref.html").
For details on Radar see the following URL:
www.open.com.au/radar
For details on the Monitor clause see sections 6.61 and 23 in the manual.
regards
Hugh
On 16/12/2003, at 3:53 AM, McGrath, Thomas J. wrote:
All;
Does anyone know if you can set a different logging level for each handler?
I would like to audit a few authentication requests to the RADIUS
Radiator server for specific handlers. It would be ideal to have them set
to Trace 4 while setting other common used ones to a lower lever.
Thanks, Tom McGrath === Archive at http://www.open.com.au/archives/radiator/ Announcements on [EMAIL PROTECTED] To unsubscribe, email '[EMAIL PROTECTED]' with 'unsubscribe radiator' in the body of the message.
NB: have you included a copy of your configuration file (no secrets), together with a trace 4 debug showing what is happening?
-- Radiator: the most portable, flexible and configurable RADIUS server anywhere. Available on *NIX, *BSD, Windows, MacOS X. - Nets: internetwork inventory and management - graphical, extensible, flexible with hardware, software, platform and database independence. - CATool: Private Certificate Authority for Unix and Unix-like systems.
=== Archive at http://www.open.com.au/archives/radiator/ Announcements on [EMAIL PROTECTED] To unsubscribe, email '[EMAIL PROTECTED]' with 'unsubscribe radiator' in the body of the message.