On 06/29/2012 03:56 AM, Adam O'Reilly wrote: > We are investigating a problem on our wimax sessions table: device_session > > As it is getting quite large is there an option to clean up this table > when the wimax session is torn down.
Radiator does not have a built-in cleanup for the old entries, so you would need e.g., a cron job for this. Column key_expires is set to time() + KeyLifetime so you could consider cleaning up old rows based on this column. -- Heikki Vatiainen <[email protected]> Radiator: the most portable, flexible and configurable RADIUS server anywhere. SQL, proxy, DBM, files, LDAP, NIS+, password, NT, Emerald, Platypus, Freeside, TACACS+, PAM, external, Active Directory, EAP, TLS, TTLS, PEAP, TNC, WiMAX, RSA, Vasco, Yubikey, MOTP, HOTP, TOTP, DIAMETER etc. Full source on Unix, Windows, MacOSX, Solaris, VMS, NetWare etc. _______________________________________________ radiator mailing list [email protected] http://www.open.com.au/mailman/listinfo/radiator