I'm playing with running multiple instances of RADIATOR on the same windows box to improve RADIATOR performance.
I have a "Master" instance of RADIATOR that proxies incoming requests from my NAS boxes (wireless controllers) to one of four "slave" instances using <AuthBy HASHBALANCE>. However, I need to use different Handlers based on the incoming NAS box. Using a single instance of RADIATOR I would just use "Identifier" keyword in the <Client> configuration clause and pick a Handler using "Client-Identifier" selector in the <HANDLER> clause. Is there a way to pass the "Client-Identifier" to another RADIATOR process ? Perhaps as an RADIUS Attribute ? Thanks. -Neil -- Neil Johnson Network Engineer The University of Iowa Phone: 319 384-0938 Fax: 319 335-2951 Mobile: 319 540-2081 E-Mail: [email protected]
_______________________________________________ radiator mailing list [email protected] http://www.open.com.au/mailman/listinfo/radiator