Hi, On 03/26/2014 06:40 PM, Roberto Pantoja wrote: > I have a problem trying to assign dynamic VLANs to users on a > WPA2-Enterprise configuration. Users have successful authentication and > if I don't send the Radius Attribute "Tunnel-Private-Group-ID" The > Wireless Controller connects me to the default VLan for the SSID, but > when I send "Tunnel-Private-Group-ID", the Wireless Controller simply > drops out my connection. The Wireless controller documentation says the > required attributes in the Access-Accept Reply are "Tunnel-Type=VLAN, > Tunnel-Medium-Type=802, Tunnel-Private-Group-ID=<Name of VLAN>". > Everything works fine using Ignition Server (Avaya's Radius Server). But > on product's documentation says WC8180 comply with RFC Standards and > mentions to be "compatible and validated" with freeradius and Microsoft > IAS, so I think my case is a configuration issue.
Are you sure that it's Tunnel-Type=VLAN, Tunnel-Medium-Type=802, Tunnel-Private-Group-ID=<Name of VLAN> for your wireless controller? We have an HP ProCurve WLAN Controller and I have to send: Tunnel-Type = 13, Tunnel-Medium-Type = 6, Tunnel-Private-Group-ID = <vlan-id> It's the same for our LANCOM Access Points which are autonomous (no controller). I found a document "Avaya WLAN 8100 Fundamentals" regarding AVAYA WC8180 WLAN Controller. They say WC8180 is part of the WLAN 8100 solution. http://198.152.212.23/css/P8/documents/100161076 (PDF file) On page 87 they talk about authorization attributes: Tunnel-Private-Group-Id: Mobility VLAN Name Tunnel-Medium-Type: The value is 6 (IEEE 802) Tunnel-Type: The value is 13 (VLAN) So perhaps you have to send Tunnel-Type=13, Tunnel-Medium-Type=6, Tunnel-Private-Group-ID=<Name of VLAN> Apart from that: is it possible to proxy the request of the controller through radiator to the Ignition Server i.e. to configure the radiator server as a client on the Ignition Server? Then you'd see all attributes that the Ignition Server is sending in the radiator debug log. Regards Klara -- Karlsruher Institut für Technologie (KIT) Steinbuch Centre for Computing (SCC) Klara Mall Netze und Telekommunikation (NET) Hermann-von-Helmholtz-Platz 1 76344 Eggenstein-Leopoldshafen Telefon: +49 721 608-28630 Telefon: +49 721 608-48946 E-Mail: [email protected] Web: http://www.scc.kit.edu KIT - Universität des Landes Baden-Württemberg und nationales Forschungszentrum in der Helmholtz-Gemeinschaft _______________________________________________ radiator mailing list [email protected] http://www.open.com.au/mailman/listinfo/radiator