Wed, Jan 23, 2019 at 02:25:22PM +0000, Pedrosi, Derek G.: > Hello, > > I am backing up Arista devices using RANCID and works great, version > 3.7. Is there a way to ignore the following timestamped lines for > power supplies ? > > - !Power Supply 1: PWR-460AC-R Ok 122 days, 21:25:53 > > + !Power Supply 1: PW-460AC-R Ok 123 days, 21:25:51 > > There was a reply to this in Sept 2018, but the OP never followed up. > > > heasly guessed it was the "sho env all" command and asked to see the output > of it... > > Here is the pertinent part... > > Power Input Output Output > Supply Model Capacity Current Current Power Status Uptime > ------ ----------- -------- ------- ------- ------ ---------- ---------------- > 1 PWR-460AC-R 460W 0.00A 0.00A 91.0W Ok 124 days, > 21:06:11 > 2 PWR-460AC-R 460W 0.50A 7.75A 91.0W Ok 124 days, > 21:06:11 > Total -- 460W -- -- 91.0W -- --
i believe this was fixed in 3.8 when the format changed. _______________________________________________ Rancid-discuss mailing list [email protected] http://www.shrubbery.net/mailman/listinfo/rancid-discuss