so -2 or lower works? On Wed, Feb 20, 2019 at 12:37 PM Emille Blanc <emi...@abccommunications.com> wrote: > > These are all from an EX2200-C-12T-2G's, running 12.3R12.4 > We're stuck at that release for the 2200-C's, as 15.x bricks them in our > environment (TSB17138 does warn to not use 15.x). > > > I just saw your comment in the patch that N/A only appeared for a > > temperature in the range -1 to 0. > > Correct - last I dug into this, it only reports N/A at 0 (zero), and -1 > degrees. It always struck me as an odd cosmetic. > > -----Original Message----- > From: Rancid-discuss [mailto:rancid-discuss-boun...@shrubbery.net] On Behalf > Of Anderson, Charles R > Sent: Wednesday, February 20, 2019 9:20 AM > To: rancid-discuss@shrubbery.net > Subject: Re: [rancid] [PATCH] junos.pm: filter negative temperatures in > ShowChassisEnvironment > > My example below WAS from an EX2200. We have some others that always report > -10 (even in toasty closets)--I wonder if that is off-scale low due to a > sensor failure? I have also seen N/A in 2016, but not lately. What software > version are you running? We are running 12.3R12-S2 on this particular > outdoor EX2200. I can try to find out what version we were running in 2016 > when we last saw N/A. I just saw your comment in the patch that N/A only > appeared for a temperature in the range -1 to 0. > > On Wed, Feb 20, 2019 at 08:54:39AM -0800, Emille Blanc wrote: > > Ironically, we rely on RANCID to tell us when our cabinets get too cold on > > such devices. > > Mostly because our NMS is hopeless, and can't do it (Enterprise! Closed > > source!), so it never occurred to me to submit a patch for this. > > > > However, some devices (namely, EX2200's) don't understand zero, or sub-zero > > degrees and report it as N/A. > > I've attached a patch to cover this circumstance. > > > > # Class Item Status > > # Power FPC 0 Power Supply 0 OK > > # Temp FPC 0 GEPHY1 OK > > - # FPC 0 GEPHY2 OK N/A > > + # FPC 0 GEPHY2 OK > > # FPC 0 GEPHY3 OK > > # FPC 0 GEPHY4 OK > > # > > > > -----Original Message----- > > From: Rancid-discuss [mailto:rancid-discuss-boun...@shrubbery.net] On > > Behalf Of Anderson, Charles R > > Sent: Tuesday, February 19, 2019 6:50 AM > > To: rancid-discuss@shrubbery.net > > Subject: [rancid] [PATCH] junos.pm: filter negative temperatures in > > ShowChassisEnvironment > > > > One of our switches is in an outdoor cabinet. It gets below 0 sometimes so > > we see output like this: > > > > # Temp FPC 0 GEPHY1 OK > > # FPC 0 GEPHY2 OK > > # FPC 0 GEPHY3 OK > > - # FPC 0 GEPHY4 OK -5 degrees C / 23 > > degrees F > > + # FPC 0 GEPHY4 OK > > # > > > > The attached patch fixes ShowChassisEnvironment so it matches the - sign. > > _______________________________________________ > Rancid-discuss mailing list > Rancid-discuss@shrubbery.net > http://www.shrubbery.net/mailman/listinfo/rancid-discuss > > _______________________________________________ > Rancid-discuss mailing list > Rancid-discuss@shrubbery.net > http://www.shrubbery.net/mailman/listinfo/rancid-discuss
_______________________________________________ Rancid-discuss mailing list Rancid-discuss@shrubbery.net http://www.shrubbery.net/mailman/listinfo/rancid-discuss