Ooops!  I forgot to mention.  That part works fine!       The Report |
Action | Before Generate .eep 

I can create it and it runs fine - The report, but where would you DROP the
temp table?

It would be nice if it was all inclusive in the "Report | Action"  however
if you drop the table after generate and then go to designer it will fail to
find temp Table. So I have "Drop tTable in my eep that runs this report
(then not inclusive in the report)  Because the tTable got dropped (The
Report | Action |?  Tried several options).  I suppose I could insert a "if
vuser = me   then   ....   ....  ...   do not drop tTable"  in order to keep
the tTable so report Designer will work.  But I was only wondering if there
is an easier way.   

At the moment I just had to create the tTable first and then use the report
designer.  I had to this morning to get the work around.



I think I'm nit picking here also.    I just thought I would ask, seemed
like a good day (not many posts).



Sincerely,
Paul Dewey 









-----Original Message-----
From: [email protected] [mailto:[EMAIL PROTECTED] On Behalf Of MikeB
Sent: Wednesday, July 30, 2008 11:44 AM
To: RBASE-L Mailing List
Subject: [RBASE-L] - Re: Report | Action

create your temp table for the Design session in the "onBeforDesign" eep...



----- Original Message ----- 
From: "Paul InterlockInfo" <[EMAIL PROTECTED]>
To: "RBASE-L Mailing List" <[email protected]>
Sent: Wednesday, July 30, 2008 11:36 AM
Subject: [RBASE-L] - Report | Action


Curious thought and looking for options.



If you create a temp table in a Report|Action  Example:

SET ERROR MESSAGE 2038 OFF

DROP TABLE tinstall

PROJECT TEMPORARY tinstall FROM cust USING ALL WHERE install > (#DATE - 365)

ORDER BY install DESC

SET ERROR MESSAGE 2038 ON



Where would YOU drop the tTable.  If you do it in one of the actions, it
seems 
you stop your ability to use the report designer (of course you can
pre-create 
a temp table) but is there another way in actions that is short and sweet
(less 
than 50 lines of code). I am now just dropping the table in the .eep that 
launched the report.



















Sincerely,

Paul Dewey





New Horizon Interlock Inc.

New Horizon Safety Diagnostics Inc.

www.interlockinfo.com

Saving Lives - One Breath at A Time  T



This e-mail message is intended only for the named recipient(s) above and is

covered by the Electronic Communications Privacy Act 18 U.S.C. Section 
2510-2521. This e-mail is confidential and may contain information that is 
privileged or exempt from disclosure under applicable law. If you have
received 
this message in error please immediately notify the sender by return e-mail
and 
delete this e-mail message from your computer.


Reply via email to