You will get this error if you do not remove the report from the
sys_reports3 table when you try to reload the same report data. You
would need to delete the report first, then reload it. If you are using
7.x and correcting reports I suggest you use the [Unload] option in the
database manager > reports section. The resulting files will have a
'drop report xyx' at the top and prevent the error.
cdconrad wrote:
I have made corrections to a series of reports in a backup of the main
database.
I have done both unload all and unload data from the sys_reports3
table but when I load it in the main database I get an error saying
the data must be unique.
Any suggestions.
Chuck
- [RBASE-L] - Re: Transfer of sys_reports3 data Albert Berry
-