Bernie, My code is in the "on row entry" EEP but I have used the same type of code in other areas of forms.
I saw that you were setting the BLINKINTERVALON in your code. I use the settings in the field rather than controlling via the EEP code. If you set the blink interval in your EEP I think that you will need a BLINKINTERVALOFF as well as a BLINKINTERVALON. John -----Original Message----- From: [email protected] [mailto:[EMAIL PROTECTED] On Behalf Of Bernard Lis Sent: Sunday, March 13, 2005 12:51 PM To: RBG7-L Mailing List Subject: [RBG7-L] - Re: blinking John, Where do you locate this eep? I tried putting it into forms properties in "after start" I still can't get it to blink. Bernie Lis ----- Original Message ----- From: "John Engwer" <[EMAIL PROTECTED]> To: "RBG7-L Mailing List" <[email protected]> Sent: Wednesday, March 09, 2005 7:02 AM Subject: [RBG7-L] - Re: blinking > Bernie > > This code works for me in one of my applications. > > IF .vAMT_OWED > 0 THEN > PROPERTY idAMT_OWED BLINKING 'TRUE' > PROPERTY idAMT_OWED BLINKCOLOR 'red' > ELSE > PROPERTY idAMT_OWED BLINKING 'FALSE' > ENDIF > > Settings at the "Blinking tab" are: > Blinking is not checked > Blink interval on: 556ms > Blink interval off: 556ms > > John > > -----Original Message----- > From: [email protected] [mailto:[EMAIL PROTECTED] On Behalf Of Bernard Lis > Sent: Tuesday, March 08, 2005 6:14 PM > To: RBG7-L Mailing List > Subject: [RBG7-L] - Re: blinking > > Hi Emmitt, > Yes, I tried moving the visible up to top and still no blinking. > My eep now looks like this: > > SELECT alertflag INTO vflag FROM customer WHERE customerno=.cno > IF vflag = 'Y' THEN > PROPERTY CustAlert visible 'TRUE' > PROPERTY CustAlert BLINKING 'TRUE' > PROPERTY CustAlert BLINKINTERVALON '500' > PROPERTY CustAlert BLINKCOLOR 'red' > ELSE > PROPERTY CustAlert visible 'False' > ENDIF > RETURN > > I've also tried changing the interval from 2 to 20 to 200 to 500 > I also tried to make it a var label instead of a static text. > > Bernie Lis > > ----- Original Message ----- > From: "Emmitt Dove" <[EMAIL PROTECTED]> > To: "RBG7-L Mailing List" <[email protected]> > Sent: Tuesday, March 08, 2005 2:05 PM > Subject: [RBG7-L] - Re: blinking > > >> Bernie, >> >> Have you tried setting the blinking property AFTER you make it visible? >> >>>I cannot get a static text field to blink. >>>I have the following custom eep in "after start" >>> >>>SELECT alertflag INTO vflag FROM customer WHERE customerno=.cno >>>IF vflag = 'Y' THEN >>> PROPERTY CustAlert BLINKINTERVALON '2' >>> PROPERTY CustAlert BLINKCOLOR 'aqua' >>> PROPERTY CustAlert BLINKING 'TRUE' >>> PROPERTY CustAlert visible 'TRUE' >>>ELSE >>> PROPERTY CustAlert visible 'False' >>>ENDIF >>>RETURN >>> >>>CustAlert is the component id in the static text field >>> >>>I also tried setting the blinking interval in the field property >>> >>>I would appreciate any help on this blinking project >>> >>>Bernie Lis >> >> Emmitt Dove >> Manager, DairyPak Business Systems >> Blue Ridge Paper Products, Inc. >> 40 Lindeman Drive >> Trumbull, CT 06611 >> (203) 673-2231 >> [EMAIL PROTECTED] >> [EMAIL PROTECTED] >> >> > >