Bernie,

My code is in the "on row entry" EEP but I have used the same type of code
in other areas of forms.  

I saw that you were setting the BLINKINTERVALON in your code.  I use the
settings in the field rather than controlling via the EEP code.  If you set
the blink interval in your EEP I think that you will need a BLINKINTERVALOFF
as well as a BLINKINTERVALON.

John

-----Original Message-----
From: [email protected] [mailto:[EMAIL PROTECTED] On Behalf Of Bernard Lis
Sent: Sunday, March 13, 2005 12:51 PM
To: RBG7-L Mailing List
Subject: [RBG7-L] - Re: blinking

John,
Where do you locate this eep?
I tried putting it into forms properties in "after start"
I still can't get it to blink.
Bernie Lis

----- Original Message ----- 
From: "John Engwer" <[EMAIL PROTECTED]>
To: "RBG7-L Mailing List" <[email protected]>
Sent: Wednesday, March 09, 2005 7:02 AM
Subject: [RBG7-L] - Re: blinking


> Bernie
> 
> This code works for me in one of my applications.
> 
> IF .vAMT_OWED > 0 THEN
>       PROPERTY idAMT_OWED BLINKING 'TRUE'
>       PROPERTY idAMT_OWED BLINKCOLOR 'red'
>    ELSE
>       PROPERTY idAMT_OWED BLINKING 'FALSE'
> ENDIF
> 
> Settings at the "Blinking tab" are:
> Blinking is not checked
> Blink interval on: 556ms
> Blink interval off: 556ms
> 
> John
> 
> -----Original Message-----
> From: [email protected] [mailto:[EMAIL PROTECTED] On Behalf Of Bernard Lis
> Sent: Tuesday, March 08, 2005 6:14 PM
> To: RBG7-L Mailing List
> Subject: [RBG7-L] - Re: blinking
> 
> Hi Emmitt,
> Yes, I tried moving the visible up to top and still no blinking.
> My eep now looks like this:
> 
> SELECT alertflag INTO vflag FROM customer WHERE customerno=.cno
> IF vflag = 'Y' THEN
>  PROPERTY CustAlert visible 'TRUE'
>  PROPERTY CustAlert BLINKING 'TRUE'
>  PROPERTY CustAlert BLINKINTERVALON '500'
>  PROPERTY CustAlert BLINKCOLOR 'red'
> ELSE
>  PROPERTY CustAlert visible 'False'
> ENDIF
> RETURN
> 
> I've also tried changing the interval from 2 to 20 to 200 to 500
> I also tried to make it a var label instead of a static text.
> 
> Bernie Lis
> 
> ----- Original Message ----- 
> From: "Emmitt Dove" <[EMAIL PROTECTED]>
> To: "RBG7-L Mailing List" <[email protected]>
> Sent: Tuesday, March 08, 2005 2:05 PM
> Subject: [RBG7-L] - Re: blinking
> 
> 
>> Bernie,
>> 
>> Have you tried setting the blinking property AFTER you make it visible?
>> 
>>>I cannot get a static text field to blink.
>>>I have the following custom eep in "after start"
>>>
>>>SELECT alertflag INTO vflag FROM customer WHERE customerno=.cno
>>>IF vflag = 'Y' THEN
>>>  PROPERTY CustAlert BLINKINTERVALON '2'
>>>  PROPERTY CustAlert BLINKCOLOR 'aqua'
>>>  PROPERTY CustAlert BLINKING 'TRUE'
>>>  PROPERTY CustAlert visible 'TRUE'
>>>ELSE
>>>  PROPERTY CustAlert visible 'False'
>>>ENDIF
>>>RETURN
>>>
>>>CustAlert is the component id in the static text field
>>>
>>>I also tried setting the blinking interval in the field property
>>>
>>>I would appreciate any help on this blinking project
>>>
>>>Bernie Lis
>> 
>> Emmitt Dove
>> Manager, DairyPak Business Systems
>> Blue Ridge Paper Products, Inc.
>> 40 Lindeman Drive
>> Trumbull, CT  06611
>> (203) 673-2231
>> [EMAIL PROTECTED]
>> [EMAIL PROTECTED]
>> 
>>
> 
>

Reply via email to