I am trying to find some electrical components but am having some
difficulty.

I am using two 450w 24v motors for drive.
I am thinking of using a Bussmann JT60060 fuse holder for circuit
protection ... what are you using?  450W/24V=18.75A*2 motors=37.5A*1.5=56.25
is a 60A fuse appropriate?
What are you using for a switch/disconnect?  I cannot find anything
reasonably priced that is rated for 60A.  I would prefer something DIN
mountable.