Darryl, If you're lifting from below ground you'll need a submersible pump to push water. Suction head maxes out at 25' at sea level before cavitation, with 1' reduction in theoretical lift capacity per 1000' above sea level. Consider a DC Quad SCS sub from SunPumps, 1-800-370-8115, to both lift and pressurize. Allan Sindelar Darryl Thayer wrote: HI all I just got a Standalone north woods 14 x 20 feet, 2 room 4 season home. It is so small I want to do most loads DC, it has been over a year since I have had this type project. |
_______________________________________________ List sponsored by Home Power magazine List Address: [email protected] Options & settings: http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org List-Archive: http://lists.re-wrenches.org/pipermail/re-wrenches-re-wrenches.org List rules & etiquette: www.re-wrenches.org/etiquette.htm Check out participant bios: www.members.re-wrenches.org