Marco,

This may be what you are looking for:
http://rredc.nrel.gov/solar/calculators/PVWATTS/version1/derate.cgi

Kent Osterberg
Blue Mountain Solar


Marco Mangelsdorf wrote:

Could someone please provide me with that generally accepted equation when it comes to estimating AC output from a PV array versus the STC rating?

 

That is, I’m looking for that equation which estimates the losses due to mod mismatch, soiling, wire losses, etc., etc.  I’ve got someone who mistakenly expects their PV array to put out 90 or more percent of the STC rating.

 

Thanks,

marco

 



_______________________________________________
List sponsored by Home Power magazine

List Address: [email protected]

Options & settings:
http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org

List-Archive: http://lists.re-wrenches.org/pipermail/re-wrenches-re-wrenches.org

List rules & etiquette:
www.re-wrenches.org/etiquette.htm

Check out participant bios:
www.members.re-wrenches.org

Reply via email to