Peter, We had a client with a SW 4024 and his system was trying to power a new Buderus boiler. The boiler controller didn't like the power quality. We cleaned up that circuit with a capacitor and has been working great since. We didn' have a sleeping issue, but he did have quite a few phantom loads.
Jay Pozner Nunatak Alternative Energy Solutions On Wed, Oct 20, 2010 at 6:40 AM, Peter Talmage <[email protected]> wrote: > I have a customer who wants to use a wall mount gas boiler on their > independent power system. Does anyone have any experience with wall mount > gas boilers that can wake up a sleeping Trace 4024 inverter and operate > correctly? What would the electrical power usage be during operation? > Thanks. > > Peter Talmage, PE > > > _______________________________________________ > List sponsored by Home Power magazine > > List Address: [email protected] > > Options & settings: > http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org > > List-Archive: > http://lists.re-wrenches.org/pipermail/re-wrenches-re-wrenches.org > > List rules & etiquette: > www.re-wrenches.org/etiquette.htm > > Check out participant bios: > www.members.re-wrenches.org > > >
_______________________________________________ List sponsored by Home Power magazine List Address: [email protected] Options & settings: http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org List-Archive: http://lists.re-wrenches.org/pipermail/re-wrenches-re-wrenches.org List rules & etiquette: www.re-wrenches.org/etiquette.htm Check out participant bios: www.members.re-wrenches.org