Lee, I think Dave Katz at AEE had a solution, although I don't remember the details. You might contact him. Allan Sindelar On 1/10/2011 12:45 PM, Lee Bristol wrote: Wrenches, Does anyone know of a UL Listed low temperature, over-voltage bypass device like the dis-continued Apollo Solar product? I need to knock out or bypass one module of a string when the temperature gets below 5 degrees F. The Apollo product was appropriate but is no longer available.Thanks! Lee |
_______________________________________________ List sponsored by Home Power magazine List Address: [email protected] Options & settings: http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org List-Archive: http://lists.re-wrenches.org/pipermail/re-wrenches-re-wrenches.org List rules & etiquette: www.re-wrenches.org/etiquette.htm Check out participant bios: www.members.re-wrenches.org