William,
It's been yrs since I dealt with this issue, and it wasn't a York specifically.. But I had an issue with a furnace and an old black Trace mod sine. A capacitor in the feed to the furnace did the trick. Dave From: [email protected] [mailto:[email protected]] On Behalf Of William Miller Sent: Thursday, March 03, 2011 7:42 PM To: RE-wrenches Subject: [RE-wrenches] York furnace Friends: Have any of you ever had problems with a York furnace on a modified sine wave inverter? What steps did you take to resolve the issues? Thanks in advance, William Miller Please note new e-mail address and domain: William Miller Miller Solar Voice :805-438-5600 email: [email protected] http://millersolar.com <http://millersolar.com/> License No. C-10-773985
_______________________________________________ List sponsored by Home Power magazine List Address: [email protected] Options & settings: http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org List-Archive: http://lists.re-wrenches.org/pipermail/re-wrenches-re-wrenches.org List rules & etiquette: www.re-wrenches.org/etiquette.htm Check out participant bios: www.members.re-wrenches.org