Hi Mac, 
 
We have used tiny RV-type propane hot water heaters (ie 1-2 gallon) situated at 
base of generator, plumbed into the coolant system with a thermostat control 
and it thermosiphons. One site has a 30 kW Kohler genset with 6 cyl GM 
industrial engine and this has been in place for 5-6 years and works reliably. 
 
Kevin

-----Original Message-----
From: [email protected] 
[mailto:[email protected]]On Behalf Of Mac Lewis
Sent: April 12, 2014 6:46 AM
To: RE-wrenches
Subject: [RE-wrenches] Propane block heaters


Hello wrenches, 

Does anyone have a good recommendation for a propane block heater product?

Thanks


-- 





Mac Lewis



"Yo solo sé que no sé nada." -Sócrates

_______________________________________________
List sponsored by Home Power magazine

List Address: [email protected]

Change email address & settings:
http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org

List-Archive: http://lists.re-wrenches.org/pipermail/re-wrenches-re-wrenches.org

List rules & etiquette:
www.re-wrenches.org/etiquette.htm

Check out participant bios:
www.members.re-wrenches.org

Reply via email to