I have a customer who has 6 siemens 48w panels that are 20 years old (hooked in parallel to a 12v battery). He says that 4 of them have failed in that there is no output unless he bypasses the diodes. However he pulled the diodes and checked them on a diode check and separately on a battery with a light bulb and they appear to be functioning correctly. Any ideas what could be causing this anomaly?
Ron Young _______________________________________________ List sponsored by Redwood Alliance List Address: [email protected] Change listserver email address & settings: http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org List-Archive: http://www.mail-archive.com/[email protected]/maillist.html List rules & etiquette: www.re-wrenches.org/etiquette.htm Check out or update participant bios: www.members.re-wrenches.org