Kirk, This is on my iPhone and I'm barely literate on it compared to my kids, so it'll likely mess up...
Use 3/4" SDR-9 black 140 psi black poly pipe with sleeved compression connectors. This has been used for years for hand installation of submersibles, down to 250-350'. I would guess that it will probably work in a 3' or larger dug well. Contact me off list if you need more. I have worked with it many times. Allan > On Oct 23, 2015, at 1:52 PM, "Kirk Herander" <[email protected]> wrote: > > Hello, > I’m replacing an old Solarjack pump with a similar Sunpump in a tiled well > about 12’ deep. I’d like to find a flexible water pipe so I can leave enough > coiled in the well to pull the pump straight out to dry land without > disconnecting. Standard poly pipe kinks too easy. Thanks. > > Kirk Herander > Owner|Principal, VT Solar, LLC > Proven PV provider since 1991 > www.vermontsolarnow.com > dba Vermont Solar Engineering > NABCEPTM 2003 Inaugural Certificant > VT RE Incentive Program Partner > 802.863.1202 > > _______________________________________________ > List sponsored by Redwood Alliance > > List Address: [email protected] > > Change listserver email address & settings: > http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org > > List-Archive: > http://www.mail-archive.com/[email protected]/maillist.html > > List rules & etiquette: > www.re-wrenches.org/etiquette.htm > > Check out or update participant bios: > www.members.re-wrenches.org >
_______________________________________________ List sponsored by Redwood Alliance List Address: [email protected] Change listserver email address & settings: http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org List-Archive: http://www.mail-archive.com/[email protected]/maillist.html List rules & etiquette: www.re-wrenches.org/etiquette.htm Check out or update participant bios: www.members.re-wrenches.org