Author: bugman
Date: Sat Nov 29 17:06:20 2014
New Revision: 26841
URL: http://svn.gna.org/viewcvs/relax?rev=26841&view=rev
Log:
The errors in the Relax_fit.test_saturation_recovery system test are now
reasonable.
They have been set to 5% of Iinf so that the chi-squared value during
optimisation is more
realistic.
Modified:
trunk/test_suite/system_tests/scripts/relax_fit_saturation_recovery.py
Modified: trunk/test_suite/system_tests/scripts/relax_fit_saturation_recovery.py
URL:
http://svn.gna.org/viewcvs/relax/trunk/test_suite/system_tests/scripts/relax_fit_saturation_recovery.py?rev=26841&r1=26840&r2=26841&view=diff
==============================================================================
--- trunk/test_suite/system_tests/scripts/relax_fit_saturation_recovery.py
(original)
+++ trunk/test_suite/system_tests/scripts/relax_fit_saturation_recovery.py
Sat Nov 29 17:06:20 2014
@@ -86,16 +86,16 @@
relax_fit.relax_time(time=times[i], spectrum_id=names[i])
# Spectrum baseplane noise for non-duplicated spectra
-spectrum.baseplane_rmsd(error=92440.562999, spectrum_id='0.070s', spin_id=None)
-spectrum.baseplane_rmsd(error=91770.380636, spectrum_id='0.150s', spin_id=None)
-spectrum.baseplane_rmsd(error=95226.122047, spectrum_id='0.250s', spin_id=None)
-spectrum.baseplane_rmsd(error=94428.183988, spectrum_id='0.350s', spin_id=None)
-spectrum.baseplane_rmsd(error=92478.391627, spectrum_id='0.500s', spin_id=None)
-spectrum.baseplane_rmsd(error=92167.856579, spectrum_id='0.750s', spin_id=None)
-spectrum.baseplane_rmsd(error=95071.442069, spectrum_id='1.000s', spin_id=None)
-spectrum.baseplane_rmsd(error=92479.274501, spectrum_id='2.000s', spin_id=None)
-spectrum.baseplane_rmsd(error=95735.516944, spectrum_id='3.000s', spin_id=None)
-spectrum.baseplane_rmsd(error=106627.326030, spectrum_id='5.000s',
spin_id=None)
+spectrum.baseplane_rmsd(error=5e13, spectrum_id='0.070s', spin_id=None)
+spectrum.baseplane_rmsd(error=5e13, spectrum_id='0.150s', spin_id=None)
+spectrum.baseplane_rmsd(error=5e13, spectrum_id='0.250s', spin_id=None)
+spectrum.baseplane_rmsd(error=5e13, spectrum_id='0.350s', spin_id=None)
+spectrum.baseplane_rmsd(error=5e13, spectrum_id='0.500s', spin_id=None)
+spectrum.baseplane_rmsd(error=5e13, spectrum_id='0.750s', spin_id=None)
+spectrum.baseplane_rmsd(error=5e13, spectrum_id='1.000s', spin_id=None)
+spectrum.baseplane_rmsd(error=5e13, spectrum_id='2.000s', spin_id=None)
+spectrum.baseplane_rmsd(error=5e13, spectrum_id='3.000s', spin_id=None)
+spectrum.baseplane_rmsd(error=5e13, spectrum_id='5.000s', spin_id=None)
# Peak intensity error analysis.
spectrum.error_analysis()
_______________________________________________