Hi Edward,

I was wrong on the I0 / rx error values:

On 07.02.2013, at 18:24, Martin Ballaschk <[email protected]> wrote:

>> For the spins where m0 are selected, do their errors look larger than
>> the other spins?  Or if you plot the I0 values from the relaxation
>> exponential curve-fitting, are these residues much lower than the
>> rest?  


There is a tendency, but I don't know if that is what you mean by "much lower". 

Have a look at these files: Boxplots of rx, rx_errors and i0 for each model: 

@ 600: https://dl.dropbox.com/u/4019316/boxplots_600.pdf
@ 750: https://dl.dropbox.com/u/4019316/boxplots_750.pdf

Regards,
Martin


_______________________________________________
relax (http://www.nmr-relax.com)

This is the relax-users mailing list
[email protected]

To unsubscribe from this list, get a password
reminder, or change your subscription options,
visit the list information page at
https://mail.gna.org/listinfo/relax-users

Reply via email to