There two initialization methods: the first is complete, erasing all codes and setting the programming enable 1 & 2, and programming disable to their default values. To perform this procedure, ground IC U1, pin 7 and (while the pin is grounded) enter DTMF "AAA".
The second procedure will only set the programming enable 1 & 2, and programming disable to their default values. It not affect any other data. To perform this procedure, ground IC U1, pin 7 and (while the pin is grounded) enter DTMF "AAB". Hope this helps. If you don't have the manual, you can download the online version from MCC's website http://home.earthlink.net/~mccrpt/. Richard, N7TGB -----Original Message----- From: va3vkk [mailto:[EMAIL PROTECTED] Sent: Tuesday, November 18, 2003 11:26 AM To: [email protected] Subject: [Repeater-Builder] RC-1000 repeater controller Unable to gain access after I made my adjustments. The adjustments I made were accepted. I was unable to exit or for that matter get back in. The repeater response to user code functions like touch tone pad test. I powered down the unit & restored power that did not help. Dose any one know if the is a way to reset this locally? It would be nice to know what happens on reset also like what gets erased va3vkk Kim [EMAIL PROTECTED] Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/ Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/