Reading from the Motorola Micor "Compa Station" manual having to 
 do with this power supply: for TPN1105A and TPN1106A ... manual 
 part number 68P81104E92 

  TPN1105A 121 or 242 V RMS 50 or 60 Hz 

  TPN1106A 121 V RMS 60 Hz 


  Factory Installed Optional Accessories: 

  C28 c/o TPN1106A, with Battery Charger 

  C38 c/o TPN1105A, with Battery Charger 

  C29 c/o C28 or C38 and the Battery Protection and Alarm 


  Description: 

    The C28, C38 and C29 options are factory 
 installed accessories that are available for all
 models of Motorola "Micor" base and repeater 
 stations, either locally or remotely controlled.  

  * The C28 option permits the station to oper- 
 ate from 121 volt, 60 Hz ac power normally, but 
 provides continued operation from 12-volt bat- 
 teries (emergency power) if the ac power should 
 fail.  When ac power is restored, the power 
 supply also operates as a battery charger to re-
 charge the batteries. 

  * The C38 option is the same as the C28 op-
 tion except that it operates from 121 or 242 volt, 
 50 or 60 Hz ac power, as well as 12 volt batteries. 

  * The C29 option is available only if the C28 
 or C38 power supply/battery charger option is 
 also included.  The C29 option is a Battery Pro- 
 tection & Alarm package that can be factory 
 installed, to improve emergency power backup by 
 providing an audible alarm whenever the station 
 is operating on batteries.  The battery protection 
 and alarm option generates an audible alarm tone 
 which "beeps" to indicate that the station is oper- 
 ating on emergency power.  This tone burst, with 
 a frequency of about 1400 Hz, is approximately 
 1/4 second long and repeats at 2 1/2 second inter- 
 vals.  On remote control stations, or repeater 
 station with wire line control, the alarm tone is
 injected into the audio line and is heard at the 
 console (except when transmitting).  On repeater 
 stations, without wire line control, the tone is 
 transmitted whenever the transmitter is keyed, 
 so that anyone receiving signals from this station 
 will know that it is operating on emergency power. 

  (The description continues ...)   


  As I remember, the output voltage (battery charging voltage) 
 control is behind two chassis panels and one circuit board.  All 
 must be removed prior to making the voltage adjustment.  (Be 
 careful)  The fix for this is to drill holes in those chassis 
 panels and the circuit board before installing the power supply 
 ... and then use an insulated tool to make the adjustment. 

  The only relay involved with these power supplies is the discharged 
 battery disconnect relay that comes with the C29 option. 

  Hope this helps, 

  Neil McKie - WA6KLA 



Eric Lemmon wrote:
> 
> Kelly,
> 
> It would have been nice, had you included those seven numbers in 
> your posting.  But, by your description, I think you have either 
> the TPN1105A or TPN1106A power supply.  The model number is usually 
> stamped on a box that is immediately below the large black 
> transformer.  The TPN1105A operates only on 120 VAC 60 Hz, while 
> the TPN1106A can operate on either 120 VAC or 240 VAC, and 50 or 60 
> Hz.  I believe that you have one of these units, because your 
> description of a "squeal" as it starts tells me that it incorporates 
> a switching power supply circuit.  Earlier units were linear in 
> design, and made no such noise.
> 
> Either of the above units may be equipped with Option C29, called 
> the Battery Protection & Alarm option.  This provides a relay closure 
> when AC power fails, and it also injects a periodic beep into the 
> audio to alert the users that it is on battery power.  The C29 option 
> also can lower the PA power when on batteries, and shut down the 
> repeater when the battery voltage falls below a safe level.
> 
> These power supplies can be adjusted, with an internal pot, to float
> nicad batteries at 14.25 VDC or lead-acid batteries at 13.0 VDC.  
> Before connecting your power supply to any batteries, you should 
> check and/or adjust the voltage to the proper level using an accurate 
> DVM.  Most MICOR stations installed with battery backup used Motorola 
> nicad batteries rather than lead-acid, so don't assume that the 
> voltage is set for the latter.
> 
> Obtain Motorola publication 6881104E92 for operation and service
> information.
> 
> 73, Eric Lemmon WB6FLY
> 
> [EMAIL PROTECTED] wrote:
> >
> > I have acquired a couple of the Micor Power Supplies with the 
> > Battery Charger. Now I asked the local Motorola shop about 
> > purchasing a service manual.  They are more than happy to help, 
> > but need the typical xxxyyyyz part number. Well, there are 7 such 
> > numbers stamped on various places of the unit. These are probably 
> > subassembly part numbers.
> >
> > Let me describe the thing and no doubt some of you will recognize 
> > it. It is heavier than other Micor power supplies, has a larger 
> > heat sink, and squeaks when powered up. There is apparently an 
> > audio signal and PTT(can I use that acronym anymore) to indicate 
> > battery mode, and a low voltage shutoff adjustment. I'd really 
> > like to make use of these features. Do any of you recognize it? 
> > If you do I need to order a service manual for this model. If you 
> > happen to have a manual that could be parted with, please let me 
> > know.
> >
> > Kelly Fowler, KE4ADV
> >
>



 

Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/ 


Reply via email to