Well after 5 Days of working with a friend Who worked on a lot of
Motorola mobile
micor  hts but has never worked on the Micor Unified Repeater,
Numbers on unit TCN-1187A  TLN5649A I Use The TLN5900A Test 
Set and His Motorola Service monitor Transmit is ok Both xtals ok, 
There is no audio coming out of the test speaker Vol and Well 
after 5 Days of working with a friend Who worked on a lot of Motorola
mobile Sq  on unit makes no difference. We have changed out 
boards  both receivers work  on meter good sens. Both pl works two
different power supplies tried both work I did go look at the 
repeater builder site.  Cards in unit line driver , Station control  
Paging/dc transfer and Sq card. And receiver and audio sq board Any 
one had a problem like this that can offer some trouble shooting
suggestions will be greatly appreciated it is being set up as a Ham 
repeater on 444.750 xtals are from international and are good. 
E-mail Me direct will be fine too. And Yes it did Work fine for about
Ten 
MIN.

Thanks Don KA9QJG 





 