If one of the group finds they have some extra ferrite slugs I would be interested in buying one. Please contact me off list [EMAIL PROTECTED]
Thanks - Larry ----- Original Message ----- From: "Paul Kelley" <[EMAIL PROTECTED]> To: <[email protected]> Sent: Sunday, December 19, 2004 4:27 PM Subject: Re: [Repeater-Builder] GE Mastr II PLL vs. Multiplier (crystal) exciterin duplex service. > > It will come to 5 volts if you find a ferrite slug. I got > some out of an old HT... don't remember if it was a > Motorola or what, but it had the right size slugs for PLL > exciters. I *may* have more of them around, but would have > to look. > > Paul N1BUG > > > On Sunday 19 December 2004 07:01 pm, DCFluX wrote: >> I am currently running the MASTR-II PLL exciter on >> 146.640 MHz. I am running the G2 version and have never >> been able to find a ferrite core to replace the aluminum >> one. It is alot easier to tune than the multiplier >> board. Still I can only get the tune test point voltage >> to 3.6 volts and that is with the slug removed from the >> form. Recently had a problem where it was being "ghost >> keyed" with a voltage that would creep up to 1.2 volts on >> the TX osc line to the exciter. This was traced to a bad >> PNP transistor in the station control module, which was >> replaced with a radio shack MPS2907. > > > > > > > Yahoo! Groups Links > > > > > > > Yahoo! Groups Links <*> To visit your group on the web, go to: http://groups.yahoo.com/group/Repeater-Builder/ <*> To unsubscribe from this group, send an email to: [EMAIL PROTECTED] <*> Your use of Yahoo! Groups is subject to: http://docs.yahoo.com/info/terms/