--- In [email protected], "Andrew D. Hudanish"
<[EMAIL PROTECTED]> wrote:
"I cannot find in my "expertly written Motorola MSF5000 service
manual" the pinout and values of the power control cable between
the
amplifier and the RF deck. It is a six pin Molex connector with five
wires in it."
__________________________________________________
______________________
The manual you need is the big 'Depot' version, 6881082E10 - NLA from
Motorola but at least now you have the number to look for on ebay,
etc.
P502
5 - Black - ground
1 - Red - Heatsink temperature
2 - Brown - Circulator temperature
4 - Green - Forward Voltage
6 - White - not used or final reflected voltage
3 - N.C. [P.A. key]
The P.A. doesn't really care about any of those connections - they are
analog signals that go back to the station's power control circuitry.
Actual power control is applied to the IPA which is under the Uniboard
in the main casting.