Thanks Eric and Neil. Its not the info I was hoping for but is the 
info I need.

Scott Madison, WN1B





--- In [email protected], Neil McKie <[EMAIL PROTECTED]> 
wrote:
> 
>   According to my Micor manual, the TLD5953A PA Board is installed 
>  in the TLD1693E Contunuous Duty Power Amplifier on the 150.8 - 
162 
>  MHz frequency range.  
> 
>   Is this what you are looking for? 
> 
>   Neil - WA6KLA 
> 
> wn1b8 wrote:
> > 
> > I recently picked up a Micor Compa-Station exciter/PA. I know its
> > for 132-174 MHz. and I believe it to be a 100 watt PA deck, but I
> > can't seem to find what the duty cycle is. The PA board part 
number
> > is TLD5953A1093R. It has the 14 1/2" long Micor fins across the 
top
> > of the module. The module, with the fins, is 6" high.
> > 
> > I know this isn't the 100% duty cycle configuration, but can it 
be
> > run at 100% if it has constant forced air cooling across the 
fins?
> > Also, the board appears to be the same for the 100 watt 100%
> > configuration. Is it possible to simply replant this board in the
> > larger chassis/heat sink? Assuming for a moment that I could 
find a
> > dead one.
> > 
> > Any help and/or advice will be greatly appreciated.
> > 
> > Scott Madison, WN1B
> > 
> > 
> > Yahoo! Groups Links
> > 
> > 
> > 
> >







 
Yahoo! Groups Links

<*> To visit your group on the web, go to:
    http://groups.yahoo.com/group/Repeater-Builder/

<*> To unsubscribe from this group, send an email to:
    [EMAIL PROTECTED]

<*> Your use of Yahoo! Groups is subject to:
    http://docs.yahoo.com/info/terms/
 



Reply via email to