Here's the deal. The repeater we are converting is a Securenet Digital Voice Protection System Micor Repeater Station. The exciter for this station is different from the TLD8262B exciter (and others there) as shown in Kevins Micor Conversion site http://www.repeater-builder.com/rbtip/micor-index.html. So, we WERE (operative word) looking for the schematic of the mobile exciter (TLD8262B) so we could compare the component numbers and values (which are different) with the newer TLD5803B that we're converting without having to draw the circuit from the PC layout we have on hand.
Hope that clarifies what we were looking for and why. de WD7F John in Tucson ----- Original Message ----- From: "Jim B." <[EMAIL PROTECTED]> To: <[email protected]> Sent: Monday, June 20, 2005 9:20 AM Subject: Re: [Repeater-Builder] Micor mobile manual/schematic sought Budd Turner wrote: >>From another discussion group: TnT (222 in Tucson) Group > Please reply to <[EMAIL PROTECTED]> > Subject: micor mobile exciter schematic nospamk7iou > > Does anyone have a micor mobile (Trunked) manual? I need a schematic > for the exciter (TLD8262B) as our repeater has a different model > exciter due to the DVP. Since the 220 MHz conversion was done on the > mobile exciter I need the schematic to "convert" it our exciter. > 73 > Dave > http://home.comcast.net/~micorrepeater/ > > 73 > Budd : N7EOJ > TnT (222 in Tucson) Group owner The exciter model tells me it's VHF high-band. It will not be a trunked radio, maybe he means trunk-mount? And DVP means "Digital Voice Protection", Motorola's term for digital speech encryption. -- Jim Barbour WD8CHL Yahoo! Groups Links Yahoo! Groups Links <*> To visit your group on the web, go to: http://groups.yahoo.com/group/Repeater-Builder/ <*> To unsubscribe from this group, send an email to: [EMAIL PROTECTED] <*> Your use of Yahoo! Groups is subject to: http://docs.yahoo.com/info/terms/

