Well, that's one way to ensure a watertight seal. ;->

Joe M.

Jeff DePolo WN3A wrote:
> 
> > I actually saw an install where a MSS did just that - they
> > had the ground connected to a plastic water pipe!
> >
> > Joe M.
> 
> I've got a better one.  A number of years ago we changed out a 1500' run of
> 4" Heliax that had gone bad on an FM station.  Upon taking down the old line
> and looking at the damage, one of the problems we found was that the ground
> kits (approximately 8) were all installed without removing the outer jacket
> from the cable...
> 
>                                                 --- Jeff
> 
> 