skipp025 wrote:

> I'm heading toward the question of "is it better to reduce 
> or remove (mute) the ctcss after the phase shift or just 
> not worry about it?".  As mentioned in one reply... there 
> might be enough time for some fast decoders to "re-lock" on 
> the inverted ctcss before the tx drops.  200 mS might not 
> be much time but... is/does it possibly confuse some of the 
> reverse burst ctcss decoders? 
> 

It does vary quite a bit. I've seen some that close so fast that most 
radios will open it back up again, and others that close so slow that 
most radios go away before it closes.

I think a good value to use would be 160-180 mS-my opinion...
-- 
Jim Barbour
WD8CHL