At 05:04 PM 2/12/2007, you wrote:

>His failure is hardly due to running the supply right at its maximum
>continuous rating.
>NEXT?

<---I would submit that metal migration within the diodes was a 
factor in their failure. (I first heard about this when I worked at 
TRW in the 1970's and RF power transistors were still kinda "new")

http://www.ridgetop-group.com/docs/prognostic_techniques.pdf

Ken
------------------------------------------------------------------------------
President and CTO - Arcom Communications
Makers of the world famous RC210 Repeater Controller and accessories.
http://www.arcomcontrollers.com/
Authorized Dealers for Kenwood and Telewave and
we offer complete repeater packages!
AH6LE/R - IRLP Node 3000
http://www.irlp.net