At 09:59 AM 04/29/07, you wrote:
I have a Micor Station 100 VHF that was used as a paging base. I
removed the backplane and installed a "normal" one and removed the
cards for paging, and installed normal base station cards. I
completed the conversion (removing diode) for allowing the receiver
to operate all the time. Here is the problem...The receiver does
not stay on when the PTT is pushed on the station control card. Is
their a jumper I am missing somewhere?
Close, it's a diode.
Remove diode CR 957 from the receiver interconnect board. Yes, it's
a PITA to get to.
As long as you are there you will want to adjust any other jumpers
that are on that board.
Thanks,
Jim, K8COP
Mike WA6ILQ