At 6/7/2007 15:13, you wrote:
>--- In [email protected], "Tedd Doda" <[EMAIL PROTECTED]> wrote:
>
> > Bob:
> >
> > Just curious about the double braided cables like 214.
> > Wouldn't they also suffer from the same situation where
> > the 2 braids rub on each other?
>
>
>No, the key is the SILVER, which conducts extremely well whether it is
>oxidized or not.  Aluminum and copper do not exhibit this characteristic.
>
>Plus, a lot is said about dissimilar metals here, but same-metal
>braids, if not silver plated, create the same problems very often.
>RG213 should be avoided for this reason, and, the non-silver plated
>braids of some RG214, for example.

Ditto here; have found the exact same results via real-world experience.

Bob NO6B


Reply via email to