Hi All

On Superstition mountain in the Imperial Valley we have a S-COM 5K 
that has taken repeated dumps after power line failures.  The 
controller is running off an Astron 35A supply.  By dump I mean the 
only problem is that the controller has to be re-programmed after the 
AC power line failure.  Now I know there are other ways than than the 
13.5V for a glitch to get into the controller but I would suggest 
power to be the most likely.  The battery to hold up the memory has 
been replaced.

Has anyone had the same experience with that controller's problem?

I am going to try a diode in series with the power line shunted with 
a few thousand microfarads from the controller power input to 
ground.  This should give a number of seconds of hold up while junk 
may be coming down the DC power line.

Any other suggestions?

It takes more than a four wheel drive to get to this site so this is 
a killer problem.

Gran K6RIF

Reply via email to