At 12/22/2007 09:31, you wrote:

>As the last try before close down- changed the TX patch cord-Distant
>weak station came in with out any gunfire! A small added change in the
>length created less sensitivity. We made an exact length of the good
>patch cord and tried that also worked fine. Put the old one-motor boat
>came back!!
>
>A small patch cord in the whole system- which looks fine, tests fine
>created all the discomfort!

Sounds like what you really need is an isolator between the TX & 
duplexer.  Obviously your TX isn't very happy feeding a load containing a 
pure reactance 600 kHz away from your TX frequency.

Bob NO6B