One thing I will say about my TPRD duplexer and similar products 
I've bought or received from Telewave. In my opinion they then to 
set their TPRD duplexer probe insertion loss values pretty loose. 

I have had to readjust the cavity probe values (insertion loss) 
UP on some of the units I've worked with/on to obtain what I 
consider satisfactory performance. 

cheers, 
s.

> "garyp609" <[EMAIL PROTECTED]> 
> Thanks for the response. The duplexer is a Telewave TPRD1554. They 
> are brand new and bought from Tessco tuned. The cable on the RX side 
> is marked 11" in black marker on the connector and the TX side is 
> marked 11 1/2 ". Both cables terminate at the T. I just want to feel 
> assured that they are the right length as I feel my performance 
> should be much better and want to rule out the duplexer.
> Gary K2ACY


Reply via email to