Main filter caps, they like to dry out over time and also have a
tendency to explode.

On Tue, Aug 19, 2008 at 7:46 AM, wd8chl <[EMAIL PROTECTED]> wrote:
> enjoyacold807 wrote:
>> Your basic GE Mastr II rack mount pwr supply (ref PL19D436272G1 Rev
>> A) was part of club WA8UXP's 2m GE MastrII (base) repeater (146.985
>> Mhz) until it started acting up (a few years ago).  Basically, the no
>> load voltage looked ok.  But, once the 100w PA kicked in the voltage
>> swings made a sunami look like a placid lake.  Ouch!!  It was then
>> replaced by Astron RS-35A.  Now, the club has three (3) choices for
>> the old fella being: boat anchor/scrap, try to fix, or hamfest sale
>> as is.
>>
>> But option 2, hmmm, if economically repairable, maybe we could put it
>> back where it belongs (w/ the repeater) and re-deploy the Astron.
>> Ah, life, so many choices, so little time.
>>
>
> My first thought-those are ferro-resonant supplies. There's a cap across
> a special winding that provides some of the 'regulation'. If it went
> bad, I suspect it might do what your seeing...
>
> ------------------------------------
>
>
>
> Yahoo! Groups Links
>
>
>
>

Reply via email to