Hi
I have 2 MSF5000 CXB's and I run the RC210 controller on both. In the program 
there is a Kerchunk filterand I have them on. Check your program to cee if you 
have that in there. Also I have a MSF 5000 power supply TPN1185A for sale. You 
can get me at [EMAIL PROTECTED]

Bob
kd7ikz
  ----- Original Message ----- 
  From: n9lv 
  To: [email protected] 
  Sent: Sunday, August 31, 2008 8:44 AM
  Subject: [Repeater-Builder] MSF5000 Tone Issue, PL 131.8 opens cor, non 131.8 
keys repeater but no audio


  I have the analog MSF5000 repeater that has the Cat300DX repeater 
  controller installed. Not sure if this has been this way all along, 
  but I noticed there is another repeater somewhere close that has a 
  different PL. When they are using there repeater, it will cerchunk my 
  442.000 repeater. My PL is 131.8, and that will open the squelch and 
  allow audio out the repeater. Any other PL will not open the repeater, 
  but will consistanly cerchunk the repeater and causes the courtesy tone 
  to trip as well as the rest and wait id timers. Any ideas.

  Mathew



   

Reply via email to