Hmmmm
How about a mastr ii pll Vhf 147.225/147.825 with db224a @ 270' with 300' 
ldf7-50a and 110watts. I am running 45 watts right now.
Thanks
De N5NPO
Norm

----- Original Message -----
From: [email protected] <[email protected]>
To: [email protected] <[email protected]>
Sent: Sat Aug 22 10:22:36 2009
Subject: RE: [Repeater-Builder] isolation

  

My CommShop calculates 99.65 dB is required. I'd definitely be looking at a
six-cavity BpBr duplexer for this station.

73, Eric Lemmon WB6FLY


-----Original Message-----
From: [email protected] 
<mailto:Repeater-Builder%40yahoogroups.com> 
[mailto:[email protected] 
<mailto:Repeater-Builder%40yahoogroups.com> ] On Behalf Of kj4si
Sent: Saturday, August 22, 2009 6:55 AM
To: [email protected] 
<mailto:Repeater-Builder%40yahoogroups.com> 
Subject: [Repeater-Builder] isolation

Hope someone may have a program,commshop? What I need to know is what amount
of isolation with duplexers that is required for a GE m2 receiver with
.1...@12db and a m2 pll exciter,100 watt PA on vhf,600kc split?1/2in
helix,with 4pole db224 antenna at 70 ft.

thanks kj4si