Is it possible that the changing of operation frequency to MARS has caused
the PA to become unstable and the resulting spurs are causing the protection
circuit to dial back the power?  Look at the output on a spectrum analyzer
when the power loss occurs.  Also, what happens to the PA current draw and
the voltage when this problem occurs?  The power supply may be unable to
supply the needed current.

73, Eric Lemmon WB6FLY
 

-----Original Message-----
From: [email protected]
[mailto:[email protected]] On Behalf Of Hobie's Mail
Sent: Friday, January 01, 2010 10:46 AM
To: [email protected]
Subject: [Repeater-Builder] Re: MSF 5000 Army MARS repeater, Portland, OR

  

I have tried the output direct to a dummy load same result.  I use tone
access which I turned off and set the machine to squelch open, same result.
???
 
Hobie

Reply via email to