A year ago I had a low-band VHF interference problem that was caused by a solar 
charge controller. Switching from an MPPT style charge controller to a less 
efficient PWM charge controller cleared up the problem. Might be worth double 
checking by disconnecting the panels since the charge controller can, and did, 
create noise without a load. 

Brian

--- In [email protected], "brett" <brett_daw...@...> wrote:
>
> Thanks - no battery chargers on site as all solar powered.  There are solar 
> charge controllers, though I think I have discounted these.
> 
> No fluros either.
> 
> All equipment was switched off for a test, so any SMPS should have been off.
> 
> Cheers,
> Brett
> 
> --- In [email protected], DCFluX <dcflux@> wrote:
> >
> > Look around for a switch mode power supply that uses 600kHz as the
> > switch frequency.  SMPS Battery Chargers are popular for causing this.
> >  Also florescent twist lights are really good for making desense on
> > VHF.
> >
>