Sahil Takiar has posted comments on this change. ( http://gerrit.cloudera.org:8080/12163 )
Change subject: IMPALA-7087: Read Parquet decimal columns with lower precision/scale ...................................................................... Patch Set 1: Starting a new thread, since the last one was getting long. I started working on getting this patch in line with Hive's behavior - e.g. if an overflow occurs, set the row to NULL and emit a warning. I hit an issue in the design of ScalarColumnReader::ConvertSlot. The ConvertSlot method returns a bool, if true the execution continues, if false the query fails. There is no clean way for ConvertSlot to set the tuple to NULL and continue processing. ScalarColumnReader::ValidateValue on the other had does allow for this. If ValidateValue returns false, and the parse_status is ok() then the tuple is set to NULL and execution continues. If it returns false and the parse_status() is an error, it aborts the query. If it returns true, execution continues. I checked and all current implementations of ConvertSlot always return true, no matter what. So I propose changing ConvertSlot's return semantics to match those of ValidateValue. Any objections? -- To view, visit http://gerrit.cloudera.org:8080/12163 To unsubscribe, visit http://gerrit.cloudera.org:8080/settings Gerrit-Project: Impala-ASF Gerrit-Branch: master Gerrit-MessageType: comment Gerrit-Change-Id: Iafc8efd12379a39756e3e70f022a81a636dadb61 Gerrit-Change-Number: 12163 Gerrit-PatchSet: 1 Gerrit-Owner: Sahil Takiar <stak...@cloudera.com> Gerrit-Reviewer: Csaba Ringhofer <csringho...@cloudera.com> Gerrit-Reviewer: Impala Public Jenkins <impala-public-jenk...@cloudera.com> Gerrit-Reviewer: Lars Volker <l...@cloudera.com> Gerrit-Reviewer: Sahil Takiar <stak...@cloudera.com> Gerrit-Comment-Date: Thu, 10 Jan 2019 20:42:48 +0000 Gerrit-HasComments: No