Caideyipi commented on code in PR #19248:
URL: https://github.com/apache/iotdb/pull/19248#discussion_r4549657580


##########
iotdb-client/client-py/iotdb/utils/rpc_utils.py:
##########
@@ -81,10 +82,16 @@ def convert_to_timestamp(time: int, precision: str, 
timezone: str):
     try:
         ts = pd.Timestamp(time, unit=precision, tz=timezone)
     except OutOfBoundsDatetime:
+        # A datetime64 scalar keeps the input unit; pandas 3.1 otherwise 
rescales
+        # numeric input to microseconds, which can overflow millisecond values.
         try:
-            ts = pd.Timestamp(time, unit=precision).tz_localize(timezone)
-        except NotImplementedError:
-            return pd.Timestamp(time, unit=precision)
+            ts = (

Review Comment:
   [P2] Keep focused regression coverage in the final diff
   
   The second commit removes `tests/unit/test_rpc_utils.py`, so this overflow 
path has no regression test in the PR. Please retain at least a compact test 
for extreme millisecond values under pandas 3.1, including a non-UTC timezone 
and signed-boundary values; the current Python CI can pass without exercising 
the inputs that triggered this failure.



-- 