Okay, I think that this means that we need an instance of the queue per each
thread, because it seems to happen when the queue is used in multiple
queues.

On Thu, Feb 19, 2009 at 1:22 PM, chrisortman <[email protected]> wrote:

>
> When I set the threadCounts on the bus (bus is being hosted from
> RSB.Host /Action:Debug) to values greater than 1 I sometimes get this
> exception:
>
>                _message        "Property AppSpecific was not retrieved when
> receiving the
> message. Ensure that the PropertyFilter is set correctly."      string
>
> And the a debug window popping up because the code gets here
> (AbstractMsmqListener.cs):
>
>                catch (Exception e)
>                                {
>                                        Debugger.Break();
>                                        Debug.Fail("should not happen",
> e.ToString());
>                                }
>
> The failure comes from:
>                                if ((MessageType)((message.AppSpecific &
> 0xFFFF0000) >> 16) ==
> MessageType.MoveMessageMarker)
>
> >
>

--~--~---------~--~----~------------~-------~--~----~
You received this message because you are subscribed to the Google Groups 
"Rhino Tools Dev" group.
To post to this group, send email to [email protected]
To unsubscribe from this group, send email to 
[email protected]
For more options, visit this group at 
http://groups.google.com/group/rhino-tools-dev?hl=en
-~----------~----~----~----~------~----~------~--~---

Reply via email to