Germain, Yes, you could do that, but you would need to force read-repair to repopulate the node. Doing so would be nearly as expensive as simply reloading the data from the backup.
Sean Cribbs <[email protected]> Developer Advocate Basho Technologies, Inc. http://basho.com/ On Jun 8, 2010, at 4:47 AM, Germain Maurice wrote: > Hi everybody, > > I assume this question was already discussed but i didn't find the answer. > > In a production environment, we plan to use Riak with Innostore and after > Bitcask has been approved for a production environment, we will switch to it. > So, we wonder if we can, only in the migration time, switch off a node, > change its backend, > and switch it on. This could work ? > > I think the other way to do that is to backup the node, change the backend, > and restore the node. Do you agree with that ? > > Thank you. > > -- > Germain Maurice > Administrateur Système/Réseau > Tel : +33.(0)1.42.43.54.33 > > http://www.linkfluence.net > > > _______________________________________________ > riak-users mailing list > [email protected] > http://lists.basho.com/mailman/listinfo/riak-users_lists.basho.com _______________________________________________ riak-users mailing list [email protected] http://lists.basho.com/mailman/listinfo/riak-users_lists.basho.com